Our Products
Wall Supported Extension FRP Ladder
We are engaged in manufacturing of Wall supported Extension FRP Ladder, which is extra heavy duty ladder for all industrial application. Non conductive fiberglass side rail with fully serrated aluminum step.
Model Size
- LMEW 0814 – 14FT
- LMEW 1017 – 17FT
- LMEW 1220 – 20FT
- LMEW 1425 – 25FT
- LMEW 1832 – 32FT
- LMEW 2036 – 36FT
Ladder | LMEW 0814 | LMEW 1017 | LMEW 1220 | LMEW 1425 | LMEW 1832 | LMEW 2036 |
---|---|---|---|---|---|---|
FRONT & REAR Stile : | FRP-Glass Fiber C-SECTION | FRP-Glass Fiber C-SECTION | FRP-Glass Fiber TUBE SECTION | FRP-Glass Fiber TUBE SECTION | FRP-Glass Fiber TUBE SECTION | FRP-Glass Fiber TUBE SECTION |
Size of FRONT Stile : | 84x30x4.0mmTH | 84x30x4.0mmTH | 80x30x4.0mmTH | 80x30x4.0mmTH | 80x30x4.0mmTH | 80x30x4.0mmTH |
Size of REAR Stile : | 84x30x4.0mmTH | 84x30x4.0mmTH | 84x30x4.0mmTH | 84x30x4.0mmTH | 84x30x4.0mmTH | 84x30x4.0mmTH |
Steps : | FRP FLUTED PIPE | FRP FLUTED PIPE | FRP FLUTED PIPE | FRP FLUTED PIPE | FRP FLUTED PIPE | FRP FLUTED PIPE |
Size of Steps : | DIA 32mmX2.5mm TH | DIA 32mmX2.5mm TH | DIA 32mmX2.5mm TH | DIA 32mmX2.5mm TH | DIA 32mmX2.5mm TH | DIA 32mmX2.5mm TH |
Spacing bet Steps : | 305mm | 305mm | 305mm | 305mm | 305mm | 305mm |
Closed Up Size(Approx.) : | 2640x435x160 | 3270x435x160 | 3750x435x160 | 4430x435x160 | 5510x435x160 | 6210x435x160 |
Extended Length(Approx.) : | 4470mm | 5400mm | 6100mm | 7640mm | 9770mm | 11000mm |
No of Steps(Both Side) : | 8 | 10 | 12 | 14 | 18 | 20 |
Weight(Approx.) : | 16.5kg | 21.5kg | 24.8kg | 28.7kg | 38.4kg | 42.6kg |
Max. Load Cap. | 110kg | 110kg | 110kg | 110kg | 110kg | 110kg |
- Restrict ladder usage to the purpose for which the ladder is designed. Never exceed the maximum safe working load of the ladder.
- Store in areas protected from direct sunlight. Never use damaged ladder for climbing.
- Self supporting ladder such as trade ladder & platform ladder are not to be used as single ladders, that is , in the closed position.
- Keep both feet on the ladder – never put one foot on a rung/step and the other foot on a different surface.
- A non-self-supporting ladder such as an extension or single ladder, needs to be erected a minimum of one to three feet above the top support point when using for access to a roof or other work level.
- Do not step on any rung above the upper support point since this could cause the ladder to slip.
- Place your ladder on a stable, even, flat surface. Never place a ladder on top of another object.
- On a ladder or step ladder, do not over load it. The person and anything they are taking up should not exceed the highest stand on the ladder.
- On a ladder don’t move them while standing on the rungs/steps.
- Beware of electrical hazards. This is rated electrically isolating for standard utility voltages.
- Do not stand or sit on plastic top cover in trade and platform ladder.
- Always keep a secure grip. Do not use the steps if you feel tired or ill or if you suffer from vertigo or if you have recently taken alcohol.
- Wear firm flat shoes.
- For more information, please refer http://www.hse.gov.uk/pubns/indg402.pdf